Dissertationsserver


Springe direkt zu:Inhalt


Service-Navigation


Hauptnavigation/Hauptmenü: Links auf direkt erreichbare, übergeordnete Webseiten


Grafischer Identitätsbereich:




Navigation/Menü: Links auf weitere Seiten dieser Website


Navigationspfad:

Navigation: FU Dissertationen Online / Mycore 2.0.2

Drucken Icon


Objekt-Metadaten

Vergleichende seuchenhygienisch-mikrobiologische Untersuchungen an horizontal und vertikal beschickten, bewachsenen Bodenfiltern mit vorgeschalteter Mehrkammerausfaulgrube bzw. einem als Grobstoff - Fang dienenden Rottebehälter (Rottefilter)
Schwarz, Michael

Main titleVergleichende seuchenhygienisch-mikrobiologische Untersuchungen an horizontal und vertikal beschickten, bewachsenen Bodenfiltern mit vorgeschalteter Mehrkammerausfaulgrube bzw. einem als Grobstoff - Fang dienenden Rottebehälter (Rottefilter)
Title variationsComparative epidemic-hygienic-microbiological investigations on horizontal and vertically fed, artificial wetlands with upstream multi-chamber-putrid-pit and/or a rotting container (rotting filter), serving as prepurifier
Author(s)Schwarz, Michael
Place of birth: Wanne-Eickel
1. RefereeUniv. - Prof. Dr. Wolfgang Müller
Further Referee(s)Univ. - Prof. Dr. Reinhard Böhm
Univ. - Prof. Dr. Lothar Wieler
Keywordsartificial wetlands; epidemics; hygiene; microbiology; Salmonella enteritidis; waste water treatment
Classification (DDC)630 Agriculture, Veterinary medicine
SummarySix artificial wetlands, sized for the daily wastewater of 5 to 100 persons, were examined for two years monthly in each case directly and seasonally in particular as well as additionally by means of a new inspection-piece technology. The prepurifying was done either by multi-chamber-putrid-pits or rotting filters, the main cleaning was done by subsurface flow wetlands either with underground or superficial filling. The results were compared with those of rotting filter models under standardized conditions and with those of sewage treatment plants. With all examined water purification systems, carry along of epidemic exciters by means of dead and living vectors was a weak point. In contrast to a constant amount of germs in the inlet water of sewage treatment plants with a number of E. coli and faecal streptococci of on the average between log 5 and log 4 KBE/ml, a strongly varying amount of germs between log 1 and log 5 KBE/ml were found in the inlet water of decentralized artificial wetlands. The median of the number of germs in to most screened wetland "Nord-1" was for faecal streptococci in the inlet about 2,3 x log 3 CFU/ml, after the rotting filter about 9,3 x log 3 CFU/ml, after the reed patch about 9,3 x log 1 CFU/ml and after the pond about 1,8 x log-1 CFU/ml. The number of germs in the brook was not measurably changed by the wetlands outlet. By means of a new inspection-piece-technology, which prevented the washing out from germs, it could be proven that Salmonella Typhimurium survived up to 14 months in artificial wetlands as well as in rotting filters. By contaminating the wetlands with Salmonella Typhimurium a case of epidemic was simulated. In each attempt the germs passed the plants and could be isolated in the discharge at the latest after 14 days. Expectations, that the material resulting in the rotting filter would be hygienically harmless according to the defaults of the KrW/AbfG valid since 1998, was not fulfilled. In a hygienic-comparative evaluation between rotting filters and multi-chamber-putrid-pits first fared more badly. First of all because the material resulting there was too little, too firmly and too damp than that a rotting could take place so that it needed a storage time from up to 12 months to get an acceptable germ reduction. And secondly existed during this time a permanent reservoir of pathogens, which can be a special endangerment because of short infection ways in the rural area. The hygienically most justifiable way of the utili-zation of rotting filter contents was the sterilizing with at least 60 kg/m3 quicklime followed by digging up into a field. The multi-chamber-putrid-pit against it was practical to handle, operates nearly maintenance free, was operating stably, it took place a sufficient holding back of solids and the content could be delivered to a conventional sewage treatment plant. It had a minimum health risk due to the closed way of building. The only disadvantage was their small capacity for maximally two households. A sufficiently dimensioned wetland (> 2 m2/EGW), which was horizontal subsurface flowed and fed underground, was suitable to reduce hygienically relevant micro organisms sufficiently in the summer and in the winter. All other artificial wetlands reached a stable and clear cleaning achievement only by an added pond.
Documents
FUDISS_derivate_000000001011
If your browser can't open the file, please download the file first and then open it
 
FU DepartmentDepartment of Veterinary Medicine
Year of publication2003
Document typeDoctoral thesis
Media type/FormatText
LanguageGerman
Terms of use/RightsNutzungsbedingungen
Date of defense2003-05-23
Created at2003-06-15 : 12:00:00
Last changed2010-02-19 : 11:48:32
 
Old Darwin URLhttp://www.diss.fu-berlin.de/2003/139/
Static URLhttp://www.diss.fu-berlin.de/diss/receive/FUDISS_thesis_000000001011
NBNurn:nbn:de:kobv:188-2003001399
Statistics
 

 
© 2010 Universitätsbibliothek der Freien Universität Berlin | Feedback | powered by <MyCoRe>

Stand: 28.02.2010

Diese Grafiken werden nur in der Druckvorschau verwendet: